Quick navigation

Real Time Wireless Temperature and Pressure Data Logger with Flexible Sensor

Wireless Data Logger GMP RF TP F

0.01 BarA to 5 BarA
-40°C to +140°C

Real time data logger for monitoring temperature and pressure. Highly efficient (quick validation time), highly reliable (real time data), impressive accuracy (±0.1°C)

+ Collects and transmits real time temperature to XpertLog Software
+ ITS-90 Calibration coefficients are stored in the internal memory
+ Complies with FDA 21 CFR Part 11
+ Network ready: multiple users, centralized, server database, active directory authentification
+ Calibration can be performed on site
+ Can be remotely activated

Order Reference

GMP-RF-TP-F

Specifications

Characteristics

LVSC.3.2.0 - January 2022

Sensor Type

Absolute pressure / Temp: 4 wires PT-100

- flexible

430 mm (17")

- customized

up t0 5000 mm (195")

- sensor size

1.5 x 8 mm (0.06 x 0.315")

- cross section

1.77 mm2 (0.0027 inch2)

- body

0.01 Bar A to 5 BarA
-40° to +140°C

- sensor

-200°C to +200°C

Accuracy

±10 mbar ≤ 3 BarA @ 130°C
±15 mbar > 3 BarA @ 130°C
±15 mbar ≤ 3 BarA @ 23°C
±30 mbar > 3 BarA @ 23°C
±0.1°C from -40°C to +140°C

Resolution

0.1mbar; 0.01°C

Memory capacity

16,000 data points pressure / 16,000 data points temperature

Memory type

non volatile

Sampling rate

1 sec to 24 hours

Transmission

simultaneous: maximum 20 loggers
sequential: unlimited

Internal clock drift

4 sec / 24 h @ 23°C

Mechanical

- material

Peek 1000 - FDA Compliant

- enclosure

IP-68

- weight

122 g (4.30 oz)

- diameter

64.50 (2.54")

- height

51.0 mm (2.01") / 72.0 mm (2.83")

Power

2 x Lithium batteries, 0.35 g/each Lithium content
classified UN3091 under IATA DGR section 3.9.2.6
compliant with ICAO/IATA packing instructions 970,
user replaceable

Battery lifetime

Up to 6 months, based on usage

Antenna

Internal

Wireless range

121 m (400 feet)

Radio frequency

2.4 Ghz ISM band

Access point

USB to computer
Programs and reads unlimited number of loggers

Calibrations

Factory Calibrations:
User Calibrations:

traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory
closed loop calibration using XpertLog® Software

Standard Calibration Points

hysteresis at 23°C and 130°C:
• 0.05 BarA
• 0.50 BarA
• 1.00 BarA
• 1.50 BarA
• 2.00 BarA
• 2.50 BarA
• 3.00 BarA
• 3.50 BarA
• 4.00 BarA
• 4.50 BarA
• 5.00 BarA

Certifications

EMC:
Health Safety:
RF:

EN 60601-1-2 / 2007
EN 60950-1 / 2006
EN 300440-2 v.1.3.1 (2009-03)

Find out more about XpertVal 64