Real Time Wireless Temperature and CO2 Data Logger with Flexible Sensor
Wireless Data Logger GMP RF TCO2 F
0% to 20% CO2
0°C to +50°C
300 mBar to 1100 mBar (built-in pressure compensation)
GMPF CO2 RF collects real time CO2, temperature and pressure values and sends the data to XpertLog® Software. With an accuracy of ±0.5% CO2 and ±0.1°C, GMPF CO2 RF allows you to measure CO2 up to 20% and temperature from -200°C to +200°C.
• Collects and transmits real time temperature to XpertLog Software
• ITS-90 Calibration coefficients are stored in the internal memory
• Complies with FDA 21 CFR Part 11
• Network ready: multiple users, centralized, server database, active directory authentification
• Calibration can be performed on site
• Can be remotely activated
Order Reference
GMP-RF-TCO2-F
Specifications
Characteristics
LVSC.3.2.0 - January 2022
Sensor Type
CO2 - IR / Temp: 4 wires PT-100
- flexible
430 mm (17")
- customized
up to 5000 mm (195")
- sensor size
1.5 x 8 mm (0.06 x 0.315")
- cross section
1.77 mm2 (0.0027 inch2)
- body

0% to 20% CO2
0°C to +50°C
300 mBar to 1100 mBar (built-in pressure compensation)

- sensor
-200°C to +200°C
Accuracy
±0.1°C from -90°C to +140°C
±0.5% CO2 from 0% to 10% CO2
Resolution
0.01% CO2 / 0.01°C
Memory capacity
16,000 data points CO2 / 16,000 data points temperature
Memory type
non volatile
Sampling rate
1 sec to 24 hours
Transmission
simultaneous: maximum 20 loggers
sequential: unlimited
Internal clock drift
4 sec / 24 h @ 23°C
Mechanical
- material
Peek 1000 - FDA Compliant
- enclosure
IP-30
- weight
153 g (5.39 oz)
- diameter
64.5 (2.54")
- height
52 mm (2.04")
Power
2 x Lithium batteries, 0.35 g/each Lithium content
classified UN3091 under IATA DGR section 3.9.2.6
compliant with ICAO/IATA packing instructions 970,
user replaceable
Battery lifetime
Up to 6 months, based on usage
Antenna
Internal
Wireless range
121 m (400 feet)
Radio frequency
2.4 Ghz ISM band
Access point
USB to computer
Programs and reads unlimited number of loggers
Calibrations
Factory Calibrations:
User Calibrations:
traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory
closed loop calibration using XpertLog® Software
Standard Calibration Points
• 0°C
• 23°C
• 50°C
Certifications
EMC:
Health Safety:
RF:
EN 60601-1-2 / 2007
EN 60950-1 / 2006
EN 300440-2 v.1.3.1 (2009-03)