Real Time Wireless Temperature and CO2 Data Logger with Flexible Sensor
Wireless Data Logger GMP RF TCO2 F
0% to 20% CO2
0°C to +50°C
300 mBar to 1100 mBar (built-in pressure compensation)
GMPF CO2 RF collects real time CO2, temperature and pressure values and sends the data to XpertLog® Software. With an accuracy of ±0.5% CO2 and ±0.1°C, GMPF CO2 RF allows you to measure CO2 up to 20% and temperature from -200°C to +200°C.
• Collects and transmits real time temperature to XpertLog Software
• ITS-90 Calibration coefficients are stored in the internal memory
• Complies with FDA 21 CFR Part 11
• Network ready: multiple users, centralized, server database, active directory authentification
• Calibration can be performed on site
• Can be remotely activated
Order Reference
GMP-RF-TCO2-F
Specifications
Characteristics
LVSC.3.2.0 - January 2022
Sensor Type
CO2 - IR / Temp: 4 wires PT-100
- flexible
430 mm (17")
- customized
up to 5000 mm (195")
- sensor size
1.5 x 8 mm (0.06 x 0.315")
- cross section
1.77 mm2 (0.0027 inch2)
- body

0% to 20% CO2
0°C to +50°C
300 mBar to 1100 mBar (built-in pressure compensation)

- sensor
-200°C to +200°C
Accuracy
±0.1°C from -90°C to +140°C
±0.5% CO2 from 0% to 10% CO2
Resolution
0.01% CO2 / 0.01°C
Memory capacity
16,000 data points CO2 / 16,000 data points temperature
Memory type
non volatile
Sampling rate
1 sec to 24 hours
Transmission
simultaneous: maximum 20 loggers
sequential: unlimited
Internal clock drift
4 sec / 24 h @ 23°C
Mechanical
- material
Peek 1000 - FDA Compliant
- enclosure
IP-30
- weight
153 g (5.39 oz)
- diameter
64.5 (2.54")
- height
52 mm (2.04")
Power
2 x Lithium batteries, 0.35 g/each Lithium content
classified UN3091 under IATA DGR section 3.9.2.6
compliant with ICAO/IATA packing instructions 970,
user replaceable
Battery lifetime
Up to 6 months, based on usage
Antenna
Internal
Wireless range
121 m (400 feet)
Radio frequency
2.4 Ghz ISM band
Access point
USB to computer
Programs and reads unlimited number of loggers
Calibrations
Factory Calibrations:
User Calibrations:
traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory
closed loop calibration using XpertLog® Software
Standard Calibration Points
• 0°C
• 23°C
• 50°C
Certifications
EMC:
Health Safety:
RF:
EN 60601-1-2 / 2007
EN 60950-1 / 2006
EN 300440-2 v.1.3.1 (2009-03)
Applications
Interested in a demo of our 64 channels data acquisition system?

XpertVal64

Fill out the form below and we will get back to you in the shortest time possible.

Please enable JavaScript in your browser to complete this form.
Address
Name
Email